DC3R Isolation Option Board
User Guide
Instruction Manual D2-3454
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - User Guide

DC3R Isolation Option BoardUser GuideInstruction Manual D2-3454

Page 2

4DimensionsFigure 2. Isolation Option Board Mounted on a Regenerative Drive

Page 3

5InstallationATTENTION: Only qualified personnel familiar with the constuction andoperation of this equipment and the hazards involved should install

Page 4 - Contents

6InstallationFigure 4. Input Voltage Select SwitchInput voltage select switchINPUTVOLTAGESELECTSWITCHSet the input voltage select switch to 115 or 23

Page 5 - Illustrations

7InstallationSpeed adjust potentiometer connectionsFigure 5. Speed Adjust Potentiometer Connections for (a) Unidirectional Control and (b) Bidirectio

Page 6

8InstallationPolarity reversal switch connectionsTo reverse the output voltage polarity without changing the input voltage (orcurrent) polarity, conne

Page 7 - Introduction

9InstallationFigure 7. Open Collector PNP Transistor Used as a Polarity Reversal SwitchFigure 8. Polarity Reversal Using NPN TransistorPNPTRANSISTOR

Page 8 - Specifications

10CalibrationATTENTION: The following adjustments are made with power on. Exerciseextreme caution as hazardous voltage exists. Failure to observe t

Page 9

Use a voltmeter for voltage measurements.1. Switch all three of the SW501 DIP switches OFF as shown in Figure 9 (page 12).2. Connect the signal inpu

Page 10 - Dimensions

12Calibration7. Set the voltage input signal to Vimax.8. Calculate the test point voltage, Vtp:(Vimax) (m)Vtp= 2whereVomax– Vominm = Vimax– Vimin9.

Page 11 - Installation

13CalibrationCurrent input signal calibrationThe following minimum and maximum values should be known:Vomax- Maximum voltage output signalVomin- M

Page 12 - Input voltage select switch

Trademarks not belonging to Rockwell Automation are property of their respective companies. ©1999 Rockwell International Corporation.The information i

Page 13

(Iimax) (m)Vtp=2whereVomax- Vominm =Iimax- Iimin9. Adjust the SIGNAL INPUT ADJ trimmer potentiometer (P501) so that thevoltage from COM to TP (term

Page 14

15TroubleshootingBefore troubleshootingPerform the following steps before starting any procedure in this section:• Disconnect AC line voltage from th

Page 15

16TroubleshootingIf there is no output1. Measure the voltage output signal across terminals 1 and 2 (OUT1 and OUT2).If there is a DC voltage present a

Page 17 - Calibration procedure

U.S. Drives Technical Support Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: [email protected], Online: www.ab.com/support/abdrives

Page 18

iiiATTENTION: Starting and stopping with the inhibit terminal pins doesnot disconnect AC power in the stop position. A hardwired AC powerdisconnecti

Page 19 - Calibration procedure:

ivContentsIntroduction 1Specifications 2Dimensions 3Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 20

vFigure 1. Isolation Option Board Dimensions . . . . . . . . . . . . . . . . . . . . . . . .3Figure 2. Isolation Option Board Mounted on a Regenera

Page 22 - If unit does not reverse

1The isolation option board allows regenerative drives to accept agrounded or floating DC voltage or current signal.This manual contains specification

Page 23

2SpecificationsPower RequirementsLine input 115VAC/230 VAC, 50/60 Hz, single phaseInput Signal RangesVoltage signal, narrow range –25 to +25 VDCVoltag

Page 24

3DimensionsFigure 1. Isolation Option Board DimensionsALL DIMENSIONS IN INCHES [MILLIMETERS]